<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-25 10-11-50
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 63 kHz 4905 0,5097
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,8 dBr 4,92 dBr 5,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 63 kHz MIN: 14 kHz % above 76 kHz: 0,5097 Acquired: 2025/06/25 10.10.46 Total samples: 4905 Equivalent time: 0:04:05 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100
FM Scope MAX: 5,7 dBr MIN: 3,8 dBr AVE: 4,92 dBr % above 12,2 dBr: 0,0 Last value: 5,6 dBr (2025/06/25 10.10.46) 09.56 09.58 10.00 10.02 10.04 10.06 10.08 10.10 0 2 4 6 Pm [dBr]